E-Cousti Under Screed ECOBASE
Solution
Description
E-Cousti Under Screed ECOBASE Solution meets the requirements of Approved Document E. The solution is made up of a resilient layer between floor and screed combined with a structural floor of sufficient mass, incorporating a screed between 65mm and 75mm.
| Components: |
65mm Sand and Cement Screed or Proprietary Screed mass/unit area min 80kg/m2 (laid on)
E-Cousti Ecobase Under Screed (lapped over at wall junction laid on)
Concrete floor (min. mass 300kg/m2 including any bonding screed)
E-Cousti Fix and Seal and E-Cousti Ecostrip must be used to ensure the acoustic integrity of the construction |
| Mass per unit area: |
33kg/m3 |
| depth: |
5 mm |
| Fire Protection: |
60 minutes |
Technical Installation Guide
- Clean floor slab thoroughly, removing any excess concrete from the surface.
- Check floor for moisture and either dry off excess or treat with a proprietary damp proof treatment.
- Roll out the E-Cousti Ecobase lapping it up the perimeter walls and doorways by at least 100mm. At corners cut out a 45 degree piece to form a tight fit and tape using a suitable resilient tape.
- Roll out the next roll, either overlapping the previous one by at least 150mm, or closely butt joint and tape, ensuring there are no gaps.
- Any services penetrating the floor should be wrapped in E-Cousti Ecobase and the joints taped, ensuring there are no gaps.
|
|
- When laying the screed ensure that it does not penetrate between or under the joints. The screed must not touch either the structural floor or any of the perimeter walls.
- Prior to fitting plasterboards and skirting boards fold over the protruding E-Cousti Ecobase and rest the boards on top so that all hard surfaces are isolated from each other and from the screed.